{ "tables": [ { "name": "construction_sets", "data_type": "table", "refs": [ "assumption" ], "table": [ { "template": "NECB2011", "building_type": "FullServiceRestaurant", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "HighriseApartment", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Hospital", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "LargeHotel", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "LargeOffice", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": "listed as \"Crawl\" (crawlspace) in DEER" }, { "template": "NECB2011", "building_type": "MediumOffice", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "MidriseApartment", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Office", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Outpatient", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "PrimarySchool", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "QuickServiceRestaurant", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Retail", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "RetailStandalone", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "RetailStripmall", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "SecondarySchool", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "SmallHotel", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "SmallOffice", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "StripMall", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": "Note \"occupied' as default spacetype" }, { "template": "NECB2011", "building_type": "SuperMarket", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Warehouse", "space_type": "WholeBuilding", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Metal Building", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": "Mass", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_doors": "U 0.35 SHGC 0.35 Dbl LoE (e2-.1) Tint 6mm/13mm Air", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": "Glass with Curb", "exterior_skylight_building_category": "Nonresidential", "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "NECB2011", "building_type": "Automotive Facility", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Convention centre", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Courthouse", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Dining - bar/lounge", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Dining - cafeteria", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Dining - family", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Dormitory", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Exercise Centre", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Fire Station", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Gymnasium", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Health-care clinic", "space_type": "WholeBuilding", "min_stories": "2", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Health-care clinic", "space_type": "WholeBuilding", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Hospital", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Hotel", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Hotel", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Library", "space_type": "WholeBuilding", "min_stories": "2", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Library", "space_type": "WholeBuilding", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Manufacturing Facility", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Motel", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Motel", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Motion Picture Theatre", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dwelling Unit(s)", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-WoodFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Multi-unit residential", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-WoodFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dwelling Unit(s)", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Multi-unit residential", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Museum", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Office", "space_type": "WholeBuilding", "min_stories": "2", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Office", "space_type": "WholeBuilding", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Parking Garage", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Penitentiary", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Performing arts theatre", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Police Station", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Post Office", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Post Office", "space_type": "WholeBuilding", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Religious", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Retail", "space_type": "WholeBuilding", "min_stories": "2", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Retail", "space_type": "WholeBuilding", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "School/University", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "School/University", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Sports Arena", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Town Hall", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Town Hall", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Transportation", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Transportation", "space_type": "WholeBuilding", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Warehouse", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Workshop", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Warehouse - refrigerated", "space_type": "WholeBuilding", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Atrium - H < 13m", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Atrium - H > 13m", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Audience - auditorium", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Audience - auditorium", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Audience - performance arts", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Audience - motion picture", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Classroom/Lecture/Training", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Classroom/Lecture/Training", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Conf./meet./multi-purpose", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Conf./meet./multi-purpose", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-4", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-4", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dining - other", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-SteelFramed-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dining - bar lounge/leisure", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-SteelFramed-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dining - family space", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-SteelFramed-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dress./fitt. - performance arts", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Food preparation", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lab - classrooms", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lab - research", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lobby - other", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lobby - elevator", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lobby - performance arts", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lobby - motion picture", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Locker room-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Lounge/recreation", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-SteelFramed-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Washroom-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sales Area", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-SteelFramed-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Stairway-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Storage area", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Workshop space", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Automotive - repair", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-Metal-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Bank - banking and offices", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Convention centre - audience", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Convention centre - exhibit", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Courthouse - courtroom", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Courthouse - cell", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-9", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Courthouse - chambers", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Penitentiary - audience", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Penitentiary - classroom", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-9", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Penitentiary - dining", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-9", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Dormitory - living quarters", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-9", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Fire station - engine room", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Fire station - quarters", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Gym - fitness", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Gym - audience", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Gym - play", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - emergency", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - exam", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - laundry/washing", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - lounge/recreation", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - medical supply", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - nursery", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - nurses' station", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - operating room", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - patient room", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - pharmacy", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - physical therapy", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - radiology/imaging", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - recovery", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - dining", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - rooms", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - rooms", "min_stories": "2", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - rooms", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - lobby", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hotel/Motel - lobby", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hway lodging - dining", "min_stories": "1", "max_stories": "999", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hway lodging - rooms", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hway lodging - rooms", "min_stories": "2", "max_stories": "4", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hway lodging - rooms", "min_stories": "5", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-1", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Library - reading", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Library - reading", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Library - stacks", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-6", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Library - stacks", "min_stories": "2", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-1", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-A", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-B", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-C", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-D", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-E", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-F", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-G", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-H", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-I", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - detailed", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - equipment", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - bay H > 15m", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - 7.5 <= bay H <= 15m", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Mfg - bay H < 7.5m", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-3", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-3", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Museum - exhibition", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Museum - restoration", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Parking garage space", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-9", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Post office sorting", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Convention centre - audience", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-5", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Religious - fellowship hall", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-5", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Religious - pulpit/choir", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-5", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Retail - dressing/fitting", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Retail - mall concourse", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Retail - sales", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Convention centre - audience", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-8", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sports arena - court c4", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sports arena - court c3", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sports arena - court c2", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sports arena - court c1", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-8", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Sports arena - ring", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-2", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-2", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Transp. baggage", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Transp. concourse", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Convention centre - audience", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Transp. counter", "min_stories": "1", "max_stories": "1", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-4", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - fine", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk2", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "- undefined -", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Food preparation - vented", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Hospital - medical supply - occsens", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-2", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Storage area - occsens", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Storage area - refrigerated", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Storage area - refrigerated - occsens", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Metal-1", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - fine - refrigerated", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk - refrigerated", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk2 - refrigerated", "min_stories": "1", "max_stories": "1", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-Mass-6", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-2", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-1", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-1", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-6", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-6", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-1", "tubular_daylight_domes": "BTAP-Skylight-1", "tubular_daylight_diffusers": "BTAP-Skylight-1", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2012", "building_type": "Space Function", "space_type": "Office - enclosed", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2013", "building_type": "Space Function", "space_type": "Office - enclosed - occsens", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2014", "building_type": "Space Function", "space_type": "Office - open plan", "min_stories": "3", "max_stories": "999", "spandrel": "BTAP-ExteriorWall-Metal-2", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-4", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-1", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-1", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2015", "building_type": "Space Function", "space_type": "Office - enclosed", "min_stories": "1", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-3", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2016", "building_type": "Space Function", "space_type": "Office - enclosed - occsens", "min_stories": "1", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-3", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" }, { "template": "NECB 2017", "building_type": "Space Function", "space_type": "Office - open plan", "min_stories": "1", "max_stories": "2", "spandrel": "Nil", "exterior_wall_standards_construction_type": "BTAP-ExteriorWall-WoodFramed-5", "exterior_floor_standards_construction_type": "BTAP-ExteriorFloor-SteelFramed-1", "exterior_roof_standards_construction_type": "BTAP-ExteriorRoof-IEAD-3", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "BTAP-GroundContactWall-Mass-2", "ground_contact_floor_standards_construction_type": "BTAP-GroundContactFloor-Unheated-1", "ground_contact_ceiling_standards_construction_type": "BTAP-GroundContactRoof-Mass-2", "exterior_fixed_window_standards_construction_type": "BTAP-ExteriorWindow-FixedWindow-5", "exterior_operable_window_standards_construction_type": "BTAP-ExteriorWindow-OperableWindow-5", "exterior_door_standards_construction_type": "BTAP-ExteriorDoor-Metal-1", "exterior_glass_doors": "BTAP-GlassDoor-GlazedDoor-2", "exterior_overhead_door_standards_construction_type": "BTAP-ExteriorOverheadDoor-Metal-1", "exterior_skylight_standards_construction_type": "BTAP-Skylight-2", "tubular_daylight_domes": "BTAP-Skylight-2", "tubular_daylight_diffusers": "BTAP-Skylight-2", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_building_category": "Nonresidential", "exterior_roof_building_category": "Nonresidential", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_building_category": "Nonresidential", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_building_category": "Nonresidential" } ] } ] }